MPPT Controller Troubleshooting Guide
Identify the symptom, read the controller data, then work through the checks in order.
For solumex MPPT controllers using the E0–E31 code system. Menus and thresholds depend on the model manual.
01 / TRIAGE
Choose the symptom you see
Start with the closest match and jump directly to the checks.
Screen stays dark
Check battery supply, fuses and wiring.
02CHARGING CURRENT 0APV not charging
Check alarms, PV input and stop-charging conditions.
03SLOW CHARGINGInsufficient charging
Check PV, loads and cabling.
04BATTERY VOLTAGE TOO HIGHBattery overvoltage
Check alarms, battery type and other charging sources.
05ABNORMAL PV READINGSPV abnormal
Check sunlight, switches, wiring and modules.
06SCREEN SHOWS AN E CODELook up the fault code
Enter the code to see its meaning and action.
Not sure? Record four key readings first
- 1Short-press SELECT until “System Alarm” appears.
Write down the E code; E0 normally means the system is normal.
- 2Keep short-pressing SELECT through the key data.
Record battery voltage, charging current, PV voltage and PV current.
Stop immediately, keep away from the battery and follow the on-site emergency procedure.
02 / LCD DATA
How to read data with SELECT
Start from any screen and keep short-pressing until the required reading appears. During routine troubleshooting, do not long-press SELECT or press it on a settings screen because that may change parameters.
- Battery voltage
- Shows whether the battery is under-voltage, over-voltage or above the boost-charge return voltage.
- Charging current
- 0A means no charging. If low, continue with PV current and load current.
- PV voltage / current
- Indicates whether sunlight, PV switches, wiring and modules are operating normally.
- Load current
- A heavy load may consume the PV energy and prevent a full charge.
- Device / battery temperature
- At extreme temperatures, the controller may limit current or stop charging and discharging.
- System alarm
- E0 is normal. For any other E code, use the fault-code table.
Hold ENTER for three seconds to enter settings, short-press ENTER until “Boost Charge Return Voltage” appears, record the value, then hold ENTER for three seconds to exit. Do not press SELECT while viewing.
03 / DIAGNOSIS
Screen stays dark / no response
The controller normally starts from the battery side. Confirm its supply first.
- 01
Confirm the battery is connected.
Check that the battery switch, breaker and fuse are on. Battery voltage measured with a multimeter must be above 9V.
- 02
If battery voltage is 0, check the wiring.
Check for loose terminals, reversed polarity or wires clamped on insulation. Do not disconnect live wires; qualified personnel should measure live terminals.
- 03
If the screen remains dark, stop disassembling.
If supply and wiring are normal, photograph the wiring and contact technical support.
04 / DIAGNOSIS
PV not charging / battery not charging
The screen is on but charging current is 0A. Check in this order.
- 01
Check the system alarm first.
If an exclamation mark or E code appears, look it up and clear the cause first. After it disappears, perform an F01 restart.
- 02
Check PV voltage.
If PV voltage is 0, very low or below battery voltage, confirm adequate sunlight, then check the PV switch, fuse and wiring.
- 03
Check battery voltage and boost-charge return voltage.
Confirm battery type and use the return voltage shown on the screen. A new charging cycle starts only after battery voltage drops below it.
- 04
Check the charging stage.
FULL, FLOAT or a very small current usually means the battery is full or charging has stopped normally.
05 / DIAGNOSIS
Battery not charging enough
There is charging, but current is small or the battery is not full by the end of the day.
- 01
Check PV voltage and current.
If clearly low, check weather, shading, dirty modules, the PV switch and branch wiring.
- 02
Compare charging and load current.
If load current is close to or above charging current, turn off non-essential loads and observe recovery.
- 03
Check terminals and fuse holders.
Stop if terminals are hot, discolored or loose. Qualified personnel should measure cable voltage drop.
- 04
Perform an F01 restart after the checks.
Hold ENTER for three seconds, short-press SELECT to F01, press ENTER until F01 flashes, then press ENTER again.
06 / DIAGNOSIS
Battery overcharge / voltage too high
If the battery is swollen, leaking, overheated, smoking or has a pungent smell, stop charging and stay away from flames.
- 01
Check System Alarm.
Record E2 or other codes. Check whether the BMS tripped and whether controller system voltage matches the battery.
- 02
Check battery voltage and controller temperature.
If abnormally high, stop charging and check for another charger connected to the battery.
- 03
Match the on-screen battery type to the actual battery.
A mismatch applies incorrect boost, equalization and float voltages. Configure from the controller manual and battery nameplate.
07 / DIAGNOSIS
PV voltage low / absent / too high
Judge together with sunlight and system alarms; do not rely only on module nameplate power.
- 01
PV voltage is 0 or very low in daylight.
Check the PV switch, fuse, shading and wiring.
- 02
PV voltage is normal but current is low.
Possible causes include weak light, shading, dirty modules, a full battery or a disconnected branch.
- 03
Check “Daily generation Wh”.
Compare with a normal clear day without shading, not directly with module maximum power.
- 04
Stop charging if E10 appears.
E10 means PV overvoltage. Qualified personnel must check series count and cold-weather open-circuit voltage against the controller limit.
These operations can expose dangerous DC voltage and must be left to qualified personnel.
08 / ERROR CODES
Fault-code quick reference
Read the code on the “System Alarm” screen. Record it before acting. For other models, use their manuals.
| Code | Meaning | Confirmation and action | Recovery |
|---|---|---|---|
| E0 | System normal | No action needed. Record voltage, current, temperature and charging stage as a baseline. | Normal state |
| E1 | Battery over-discharge | Load output is off. Record battery voltage and load current, reduce loads and restore charging. If the icon flashes slowly, verify system-voltage detection. | Load restores above the return threshold |
| E2 | Battery overvoltage | Charging is off. Check battery type, boost/equalization/float voltages and other chargers. Treat heat, swelling or leakage as hazardous. | Auto-recovers after voltage drops |
| E3 | Battery low-voltage warning | Record battery voltage, reduce non-essential loads and confirm PV can recharge the battery. | Clears when voltage recovers |
| E4 | Load short-circuit | Disconnect the load and check cables, polarity and shorted appliances. Remove the cause before waiting for recovery. | Auto-clears after the short and recovery delay |
| E5 | Load overcurrent | Load output is off. Record load current, reduce loads and check startup surge current. | Auto-clears after overload and delay |
| E6 | Controller over-temperature | Check temperature, reduce loads, improve ventilation and clear the heatsink area. | Recovers below the threshold |
| E7 | Battery charging high-temperature protection | Check battery temperature and sensor placement, stop charging and cool the battery or environment. | Stops above 65°C; recovers below 60°C |
| E10 | Solar panel overvoltage | Charging is off. Qualified personnel should check array open-circuit voltage, series count and cold-weather Voc against the model limit. | Auto-recovers below the safe value |
| E15 | Lead-acid battery not connected | In lead-acid mode, check for a missing battery, open terminal/fuse or battery damage. | Restore connection or replace battery |
| E16 | Battery discharging high-temperature protection | Load output is off. Check battery temperature, reduce load and improve ventilation. | Off above 75°C; recovers below 70°C |
| E17 | Battery discharging low-temperature protection | Load output is off. Warm the battery according to its manufacturer; never use an open flame. | Off below −35°C; recovers above −30°C |
| E18 | Charging overcurrent protection | Charging is off. Check the array, charging-current setting and battery connections. Contact support if it recurs. | Recovers about 10 seconds after battery voltage drops |
| E19 | Battery charging low-temperature protection | Check battery temperature, stop charging and warm it per the manufacturer. | Stops below −35°C; recovers above −30°C |
| E30 | Charging/discharging disabled by system setting | Check TTL/RS485/CAN host commands, BMS or EMS instructions and registers. Do not bypass battery protection permissions. | Remove the external disable command |
| E31 | Charging overvoltage / overcurrent / reverse-polarity protection | Record battery voltage, PV voltage/current and charging current when it appears, then check polarity, array and wiring. | Auto-recovers after the abnormality clears |
| E100 | Controller restart required | The controller needs to be restarted. | Auto-recovers after restart |
Fault codes normally do not need manual clearing. They clear only after the real fault is gone and the recovery threshold is met. If the cause remains, the code stays or returns.
F01 restarts the system; F02 restores factory defaults. Use F02 only after normal troubleshooting fails, all parameters are recorded, and you can reconfigure the controller for the battery. It erases custom settings.
09 / SUPPORT RECORD
Still not solved? Record these eight items
Short-press SELECT through the pages and photograph or record the values for technical support.
Photograph the product nameplate and controller wiring. Note the date, weather and changes before and after any restart.
Power is normal but the screen stays dark; the fault returns immediately after restart; the unit is scorched, wet, broken or noisy; or the work requires opening the enclosure, disconnecting MC4 or measuring live terminals.
Contact technical support
Menus, thresholds and buttons vary by model. Always use the manual for your product. Live measurements, cable disconnection and internal repairs must be performed by qualified personnel.